For indoor heat detector applications, refer to data sheet s40980014. The world standard in mechanical heat detectors a detectafire detector is the heart of many fire protection systems. Rate compensated heat detector tester skinner innovations. Heat detector, vertical mount, 450 degrees, nc 06116317001 call for part number junction box for explosionproof heats ordering information agency file number location ul s492 ordinary ul e19310 hazardous ulc cs341e. A remote led indicator is available for models 721u, 721ut, and 741ut detectors. This enables the heat detector to communicate an alarm to the central control panel prior to reaching its fixed set point for high rates of rise, providing a timely response to both rapid and slow. Heat detector basics,heat detector typesfixed,rate of rise. The 700 series smoke detectors were the industrys first conventional selfdiagnostic detectors specifically designed for the demands of commercial and industrial environments. Typical ceiling installation of a horizontal detectafire model. Two and fourwire conventional smoke detectors kidde. And during the combustion process, smoke may be generated.
For ordinary use, they may be mounted to any approved junction box with 78 diameter opening by using 1214 npt mounting nuts. Kidde fenwal smoke detectors choose topquality fire. The sd851te photoelectric smoke thermal detector incorporates an optical chamber and a thermal element, which in turn are continually monitored by an on board processor by using algorithms developed specifically for the unit. To select appropriate temperature setting see specification on reverse. Detectafire detectors are designed for long life expectancy, however due to various field conditions it is required that the detectors be tested annually per nfpa guidelines or local fire codes. There are no required accessories for this product. Types of heat detectors cygnus wireless fire alarms blog. Bd300 is a point heat detector for detection of rise in environment temperature caused by a fire. Detectafire detectors are the heart of many fire protection systems. The 721ut provides remote alarm and trouble led driver outputs. But you may install a heat detector in places unsuitable for smoke detectors, such as attics, kitchens and bathrooms. Intelligent smartone microprocessorbased detectors continuously analyze and adjust their sensitivity to compensate for contami. Replace detectafire after any fire or heat related event, any mechanical damage, or after 10 years of continuous service.
The detector shall be an intelligent photoelectronic detector. Builtin drift compensation automatically adjusts the sensitivity if the detector. Explosionproof smoke detector conventional initiating devices df60483. Bd300 is a point heat detector for detection of rise in environment. The selfverify function ensures the highest grade of reliability. Vertical detectafire detector specifications vertical daf detectors are designed for use in both ordinary or hazardous locations. Esl 700 series conventional smoke and heat detector. Agency file number location ul s492 ordinary ul e19310 hazardous. The model 721ut photoelectric detector includes an integral fixed temperature and rateofrise heat detector. For lifesafety installations, smoke detectors must be used, in lieu of, or in addition to heat detectors. The latest line of fenwal smoke detectors offers exactly what todays demanding customer is seeking.
The daf is used for signaling overheat or fire conditions. Does having a sprinkler system abate the smoke detector requirement. Agency file number location ul s492 ordinary ul e19310 hazardous ulc cs341e ordinary and hazardous fm j. Danger this device does not protect life against fire and smoke. The hd1 heat detector uses a fenwal heat detector contact which is encased in either a marine grade alloy sm87 enclosure or a jb10 grp corrosion free enclosure. Fenwal suggests selecting a detectafire with a temperature setting a minimum of 100f abov e the maximum ambient expected temperature. T54b type e heat probe detector rugged, reliable and responsive description the t54b type e heat detector is a sealed stainless steel tubular device operating on a principle of differential coefficients of expansion. Can i use a heat detector in the place of a smoke detector.
Accepts fenwal daf 27121, 28021, 27121, 28020 rate compensated heat detectors. We are a global company offering products and technical support worldwide through a broad network. The 5600 series consists of both single and dualcircuit. Heat detectors experts in fire and security installations. The detector initiates an alarm in response to both rapid rateofrise conditions increases in excess of 15f per minute and fixed heat 5f. Life safety systems conventional initiating devices. Rate compensated detectafire unit fenwal detectafire units are ul and ulc listed and fm approved as fire detection thermostats close on temperature rise and as releasing devices open on temperature rise. This manual applies to the detector with electronics version 1.
Due to our worldwide network and large stock, we are able to deliver the equipment in a short period of time against competitive prices. Heat detector bdh300 heat detectors detectors productweb en. Fenwal controls supply globally approved controls for gas ignition, temperature control and fire and overheat detection. Medc recommend the use of stainless steel fasteners. The detector shall operate in air velocities from 500 to 4000 feet per minute. Fenwal bei lico, daf, detectafire, series 27000, series. Local pickup is now curbside delivery, but we are still shipping every day. Today, many commercial and military aircraft companies like boeing, airbus, and lockheed martin depend on fenwal sensors for detection of overheat conditions in specific aircraft zones such as wings, antiice, or bleed air ducts.
Fenwal instruction manual fenwal continuous fire and overheat detection system for industry fss publication 602 page iii 21 november 1996 list of illustrations and tables contd page figure 4. Esl 700 series conventional smoke and heat detector installation sheet description the esl 700 series smoke or smoke with rateofrise heat detectors have fieldreplaceable optical chambers. Fenwal serves oems in hvac, commercial cooking, medical, rv, industrial equipment, fire protection and many other markets. The contact in the detector closes at alarm temperature. The faster the fire rate of growth, the sooner the detectafire detector will react. Fire alarms 12 280bpl series heat detectors offer fixed temperature or combination rateofrise and fixed temperature detection. Table 6 shows three categories of fire detection devices and their relative response levels for reaction to three different rateofrise conditions.
Smartone thermal heat detector model thd7252 are thermistor based analog devices that can be programmed to respond to fixed temperature without problems associated with thermal lag. The fenwalnet 6000 fire alarm fire suppression system control unit is a compact control unit that provides one signaling line circuit, four notification appliance circuits, two releasing circuits, and four onboard relays. Fenwal controls designs and manufactures industryleading agency approved critical control products. T54b probe type heat detector i n f o r m a t i o n s h e e t description the t54b type e heat detector is a sealed stainless steel tubular device operating on a principal of differential coefficients of expansion. The 302 series activate whenever ambient air temperature reaches a detectors setting, eliminating the thermal time lag inherent in conventional heat detectors. Heat detector hazardous locations, weatherproof atex. Detectafire detection and release devices description detectafire detectors are the heart of many fi re protection systems. Detectafiredetection and release devices kidde fenwal. Model t301 normally closed contact heat detector, 360f, 182c model t301 normally closed contact heat detector, 450f, 232c junction box with mounting ears and terminal block for sensor connections. A slow rate fire figure 2 will heat the shell and struts together. The tsd1 multisensor detector can detect the early stages of fire development when there is some visible smoke andor temperature rise. Serving original equipment manufacturers with reliable products and expert technical advice for critical applications since 1935. The purpose of this note is to explain detector set point, rate compensation, and how this should affect the.
Hst series heat detector tester configuration guide hst series brochure rate compensated heat detector testing rate compensated heat detector test method comparison testing model 17343124 heat detectors testing for heat detector rate compensation. The 5600 series heat detector is intended for use in property protection applications, or for non lifesafety installations where smoke detection is not practical or appropriate. This article covers heat detector basics and heat detector types. Installation and maintenance instructions 5600 series heat. Continuous fire and overheat detection systems for industry the fenwal continuous fire detection system stands alone in its field with the unique ability to detect specific. Detectafire thermal detectors can be used with clarkes consoles or as a stand alone detector. The hd1 heat detector has been designed for use in the offshore and onshore oil, gas and petrochemical industries. The duct smoke detector shall be ul listed per ul 268a, standard for smoke detectors for duct applications, speci. If a fast rate fire figure 3 starts, the shell will expand rapidly. These units are suitable for fire alarm andor suppression. The operator does not have to view or print the entire file in order to examine relevant information.
These heat detectors are intelligent addressable detec tors that. Amerisponse the source for all your access control, audio and video, central vacuum, fire alarm, hardware and tools, home automation, intercoms, security systems, nurse call, paging and video security needs. This rate compensated device combines the best features of both fixed temperature and rateofrise detectors. Ror heat detectors may not respond to slowly developing fires. It compares fixed temperature vs rate of rise heat detectors and mentions difference between fixed temperature heat detector and rate of rise type. The detector meets nfpa 72 field sensitivity testing requirements without the need for external meters. Detectafire daf thermal detectors are ul listed, ul of canada available upon request, and fm approved detect ion and release devices used with fire detection systems to activate alarms and actuate extinguishing systems. In order to detect slowly developing fires, usually a fixed temperature element is added to the ror detector which will be activated when the element reaches the preset threshold temperature. Hst series heat detector test kits skinner innovations. Heat detector potter electric signal company, llc st. Fenwal heat detectors kidde fenwal heat sensor cable notifier addressable detectors fsc851 intelliquad multicriteria detector notifier fsv951 early warning detector notifier conventional detectors explosion proof smoke detector vesda osid fsosiria.
Nonetheless, the fenwal detectafire units should be periodically checked for proper operation. A detectafire detector is the heart of many fire protection systems. Amoxil dosage for kidney infection official online drugstore. Model 721ut photoelectric detectors include integral fixed temperature and rateofrise heat detectors. The fenwal smartone tm smoke and thermal detectors employ drift compensation. We can supply a wide range of autronica heat detectors, autronica spare parts and other autronica equipment such as input and output units and level switches worldwide. Detectafire fire and overheat detectors fenwal controls. The struts will close, actuating the alarm or releasing the agent. Horizontal type models, 2702xx must be verified at the factory. Also available is the 75u electronic heat detector head for areas too dusty for smoke detection. The fd851re thermal detector incorporates the latest in thermal element technology, the detector provides efficient and accurate detection of fires, especially in environments such as boiler houses or kitchens where smoke detectors are inappropriate due to the high level of airborne contamination. Remember that a sprinkler system relies upon heat from a fire to activate and suppress the. Hst series heat detector test kits fenwal detectafire rate compensation heat detectors. Kidde fenwal smoke detectors choose topquality fire alarm.
These types of heat detectors are the most commonly used. The detector is designed for use with autronicas interactive fire alarm systems. The t54b is available in either normally open or normally closed contact configurations. Maximum detector coverage has been determined by ul to provide detection time equal to sprinkler devices spaced at 10 ft 3 m intervals 100 sq ft. Detectors provide lowcost property protection against fire and nonlifesafety installations where smoke. Devices control the release of clean agents, co2, water or dry chemicals. These highly reliable devices have been a standard for over 65 years. Heat detectors are often used inside a bag house for fire protection and are set to activate a deluge valve. Can be used as an alarm device to sense overheat or fire. To select appropriate temperature setting see speci. The lowprofile advanced intelligent heat detectors. The detector can be removed using a screwdriver to release the tamperresistant locking finger. For rate compensated fire detectors and thermal switches. The highly reliable daf has been the standard for over 75 years.
Detection systems fenwal safety systems, a division of kidde aerospace, is a trusted name in the aerospace community. The detector is designed to operate effectively with both slow smol. Two and fourwire conventional smoke detectors kidde fenwal. Alarm indicating led operation the heat detector led turns on continuously when in alarm. System sensor is a global manufacturer of fire and life safety devices, in smoke detection, carbon monoxide detection, and notification technology. The 302 series are normallyopen devices designed especially for fire detection and alarm systems. The detector uses an optical sensing chamber to detect smoke and a fixedtemperature heat sensor to detect heat. The 302 series activate whenever ambient air temperature reaches a detector s setting, eliminating the thermal time lag inherent in conventional heat detectors. From gas stations to paint spray booths, from range hoods to large power generation systems. Uk distributor of heat detectors from fenwal controls hawco. Fenwal controls designs and manufactures industry leading agency approved critical control products.
Innovair 200 series intelligent duct smoke detectors. Fenwal continuous fire detection systems are already standard equipment in many industries. These detectors will respond to a broad range of flaming and smoldering fire conditions. This functionality requires the model 702u base and the 706u1b remote led indicator. When used with a console, a interface device id is necessary to link the heat detector to the console. Fenwal detectafire units are ul and ulc listed and fm approved as fire detection thermostats close on temperature rise and as releasing devices open on temperature rise. The heat detector is mounted via 4 off 9mm exd version or 4 off 7mm exem and exia versions fixing holes in feet on the base of the unit. Fenwal 27121725f detectafire 725f explosion proof heat. All units comprising this function are automatically tested with a calibrated test once every 24. Here it is used in combination with a sprinkler system to detect overheat and actuate an alarm. Phd low profile 800 series conventional type a1r 58c rate of rise heat detector.
Model hsta173431241 for 140 degree f detector model hsta173431242 for 325 and 425 degree f detectors. The 700 series conventional photoelectric smoke detector is an interchangeable head and base detector with a lightscattering optical sensor that provides outstanding stability and excellent response to a wide range of fires. Smoke, heat, and duct detectors application bulletin edwards. The heat detector has been designed to operate in any attitude removingreplacing the cover. Hazardous locations, weatherproof hd1 range heat detector. Maximum installation temperature 5601p, 5603, 5621, and 5623.
Horizontal heat detectors are designed for locations where appearance is a factor. Psd7152 models are smart photoelectric smoke detectors. These units are suitable for fire alarm andor suppression systems in offshore and onshore applications including. Certified data in support of use in safety functions. By ignoring transient warm air excursions, the detectafire.
Thousands of these detectors are in use controlling the release of extinguishants such as clean agents, co2, water, or dry chemicals. Model f120 triplemode uvir flame detector posted on november 12, 2015 by safetysys. The fixing holes have been designed to accept m8 exd version or m6 exeexi versions screws or bolts. Rmrs russian maritime register of shipping 1710085262. Hawcofenwal weatherproof heat detector assembly type. Description the combination rate of risefixed temperature heat sensor rha is a listed analogaddressable combination temperature heat sensor. With over 75 years of technical innovation, fenwal have continually updated and improved the design of their thermal detectors to maximise safety and efficiency. Fixed temperature models are identified fx, while combination fixed rateofrise unit s are marked fxror.
An alarm signal is only enabled in the detector once the processor. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. The detector which operates based on detection of heat or temperature is known as heat detector. For easy cleaning, the detector features a fieldreplaceable optical chamber. Heat detectors respond to changes in ambient temperature, rather than smoke.
Simplex indoor electronic heat detectors but are equipped with gold plated contacts, a high humidity thermistor, and stainless steel screws. Shock resistant, corrosion resistant, and tamperproof. In the vast majority of applications, the daf provides the ini. Properly installed and applied, the detectafire offers reliable, economical performance. These systems could avert costly downtime and serious damage even loss of life. The 700 series photoelectric smoke detector is a lowpro file, selfdiagnostic, twowire detector that monitors its own sensitivity and operational status. The photoelectric smoke detector can be used for openarea application as well as duct mounting applications with air velocity of 2000ftmin up to 4000ftmin. The 302 series can be used in all areas for any type of occupancy.
System sensor \ english us \ products \ spot \ heat detectors \ 5601p. B1 f920 general the pyrotector model 303003 explosion proof smoke detector is a sensitive yet rugged protection device that is designed for use in hazardous industrial and commercial locations. Comprising a fenwal ratecompensated detector with allstainless steel external construction, mounted to a jb10 corrosionfree grp enclosure. In most fires, hazardous levels of smoke, heat and toxic gases can build up before a heat detector. Thousands of these detectors are in use controlling the release of clean agents, co2, water, or dry chemicals. A fire is composed of heat and light, both visible and invisible.
The t54b is available in either normallyopen or normallyclosed contact configurations. Designed and tested under extreme conditions of heat, cold and humidity, u. The struts will close, actuating the alarm andor releasing the agent. Our fenwal 27121725f detectafire 725f explosion proof heat detector in new condition comes with a warranty of 90 days and fast shipping via ups. Kidde fenwal recommends that standard 4inch octagonal outlet boxes be used to mount detectors. Introduction the medc heat detector has been designed for use in hazardous environments. The attractive, functional design lends physical protection of the unit while making it suitable for residential, commercial, industrial, mercantile and public buildings, institutions and ships in nonhazardous locations those classified as ordinary under the national electric. At the set point, the unit will trigger, actuating the alarm or releasing the extinguishant. Fss cfd control unit pn 3500338, acdc 910 figure 6.